DIN Rail Power Supply

;

DIN Rail Power Supply

We are an eminent name, which is engaged in offering DIN Rail Power Supply to the clients. The offered range of DIN rail power supplies is manufactured utilizing high grade raw material and advanced machinery in strict compliance with the industry laid norms and standards. This range includes MDR Series Power Supply, SDR Series Power Supply, WDR Series Power Supply and many more items. Additionally, the offered range of DIN rail power supplies is known for its shock and vibration resistance. Products that encompass this range are suitably mentioned


General Type Three Phase or High Input Range

Main Features
  • Fanless design
  • Three phase or high input voltage range (340~550 VAC)

images/wdr-series-power-supply.jpg

General Type/Single Phase Power Supply

Main Features
  • Fan less design
  • Models over 240 W(includes) built-in PFC function

images/sdr-series-power-supply.jpg

MDR Series Power Supply

Main Features
  • No load power consumption <0.75 W (1 W for MDR-100)
  • Assemble on industrial rail TS35 / 7.5 or 15
  • Built-in active PFC and over temperature protection (MDR-100)
  • DC OK signal output (MDR-10/20)
  • DC OK relay contact (MDR-40/60/100)

images/power-supply-modular-series.jpg

Chase II Type/Step Shape Power Supply

Main Features
  • Isolation class II
  • No load power consumption <0.5 W (DR-15)
  • No load power consumption <1 W (DR-100)
  • Assemble on industrial rail TS35/7.5 or 15

images/rack-power-supply.jpg

WDR Serious Power Supply

Main Features
  • Slim design
  • 180~550 VAC wide input range (single and two phase)
  • Built-in active PFC function (240 W & 480 W)
  • Assemble on industrial rail TS35/7.5 or 15
  • Built-in DC OK relay contact

images/peripheral-dc-.jpg

SDR Serious Power Supply

Main Features
  • Slim design and high efficiency up to 94%
  • Built-in active PFC function
  • Assemble on industrial rail TS35/7.5 or 15
  • Built-in DC OK relay contact
  • 150% peak load capability

images/redundant-smps.jpg

Power Supply Modular Series

Main Features
  • Free configuration, highly flexible, customized standard PSU
  • Cover all output voltages from 1.6~53 VDC
  • Built-in active PFC
  • Suitable for multi-output, complex equipment or systems

images/smps.jpg

Rack Power Supply

Main Features
  • 19", 1U rack power unit
  • RCP-MU / RKP-CMU : Control and monitoring unit (Built-in I2C / PMBus decoder)

images/din-rail-power-supply.jpg

Peripheral DC Power Supply

Main Features
  • 20 A redundant module
  • 40 A DC UPS module

images/din-rail-power-supply-systems.jpg

N/1 Redundant SMPS

Main Features
  • Input : 195V - 230V AC, 50Hz
  • Output : 30V/67A
  • Line Regulation : 0.2% (60mV)
  • Load Regulation : 1% (300mV from 10% to 100% load change measured on sense terminal
  • Ripple &Noise : 0.5% (150mV Pk - Pk when measured with shortest probe lead length and 0.1uF/63V ceramic capacitor paralleled with 100uF/63V electrolytic capacitor across the probe tip.
  • Efficiency : Better than 80%
  • Power Factor : 0.9
  • Indication : Power ON, DC OK, C/L, I/P U/V, I/P O/V, O/T
  • Output Voltage Adj. : + 2V by front panel Vadj pot
  • Current Limit (CC type) : 70~72A
  • Output Over Voltage : 33V to 35V (Check at 10% load. (trip type) mains recycling required to restart SMPS after removing fault)
  • Input Under Voltage : (Auto Recovery Type) To be checked at 10% load. Output shuts OFF when input voltage is falls down below 185vac.
  • Input Over Voltage : (Auto Recovery Type) To be checked at 10% load. Output shuts OFF when input voltage goes beyond 264vac.
  • Over Temperature : 900c + 50c (Factory Test only)
  • Transient Response : Output should recover within 10ms for 50% step load change.
  • TTL ON / OFF : 0 - OFF; 1 - ON (if required)
  • 1O/P Current Monitoring : Scale : 70A = 10V, 67A = 9.57 (2%)
  • Operating Temperature: High : 550C Operating. Derating 2.5 % per degree C
  • beyond 500C output current is58A.(Unit is in OFF condition to be switched ON for last 1/2 hour to take the reading), Low : - 10 % Operating. (Unit is in OFF condition to be switched ON for last 1/2 Hr
  • EMI / EMC : Will meet STD461

images/solid-state-sine.jpg

SMPS( 15 Watts to 2000 watts)

Main Features
  • 15 Watts to 2000 Watts
  • Different voltages
  • Current combination with or without power factor
  • Option available in open frame construction also

images/n-redundant-power.jpg

DIN Rail Power Supply

Main Features
  • PWR-40-24 (MEAN WELL/ MDR-40-24)
  • Universal AC input / Full range, DC input
  • Protections : Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • For installation on DIN rail TS-35/7.5 or 15
  • NEC class 2 / LPS compliant (12V, 24V, 48V only)
  • LED indicator for power on
  • DC OK relay contact
  • No load power consumption<0.75W
  • 100% full load burn-in test
  • PWR-60-24 (MEAN WELL / MDR-60-24)
  • Universal AC input / Full range, DC input
  • Protections : Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • For installation on DIN rail TS-35/7.5 or 15
  • NEC class 2 / LPS compliant (12V, 24V, 48V only)
  • LED indicator for power on
  • DC OK relay contact
  • No load power consumption<0.75W
  • 100% full load burn-in test

images/power-factor.jpg